Drinking Water Branch

 

Return Links

 
 Water System Detail

 
 Water Systems

 
 Water System Search

   County Map

Glossary

 

Sample and Compliance Schedules

Water System No. : VT0005476 Federal Type : C
Water System Name : JERICHO FIRE DISTRICT 1 State Type : C
Principal County Served : CHITTENDEN Primary Source : GW
Status : A Activity Date : 09-20-1989

TCR Schedules

Sample Count Sample Type Sample Frequency Effective Begin Date Effective End Date Seasonal Start MM/DD Seasonal End MM/DD Analyte Code Analyte Name
1 RT MN 01-01-2010 1/1 12/31 3100 COLIFORM (TCR)
3 RP DL 07-22-2026 07-29-2026 7/22 7/29 3100 COLIFORM (TCR)
Total Number of Schedules Displayed = 2

Frequent Field Sample Schedules

Water System Facility State Asgn ID Water System Facility Name Analyte Code Analyte Name Days to Monitor per month Samples Required per day Effective Begin Date Effective End Date Summary Type
Total Number of Schedules Displayed = 0

Non-TCR Group Schedules

Water System Facility State Asgn ID Water System Facility Name Analyte Group Code Analyte Group Name Sample Count Sample Type Sample Frequency Current Monitoring Period Date Range Next Monitoring Period Date Range
DS001 DISTRIBUTION SYSTEM CASB CDS FOR ASBESTOS 1 RT 9Y Monitoring Completed 10-01-2031 to 12-31-2031
DS001 DISTRIBUTION SYSTEM CDB2 CDS FOR DBP STAGE 2 1 RT 3Y 08-01-2026 to 08-31-2026 08-01-2029 to 08-31-2029
DS001 DISTRIBUTION SYSTEM CL90 CDS FOR LEAD COPPER 10 RT 6M 07-01-2026 to 12-31-2026 01-01-2027 to 06-30-2027
TP001 TREATMENT PLANT 1 CCYN CDS FOR CYANIDE 1 RT 9Y 07-01-2027 to 09-30-2027 07-01-2036 to 09-30-2036
TP001 TREATMENT PLANT 1 CFLU CDS FOR FLUORIDE 1 RT 9Y 07-01-2027 to 09-30-2027 07-01-2036 to 09-30-2036
TP001 TREATMENT PLANT 1 CGA CDS FOR GROSS ALPHA 1 RT 6Y 04-01-2031 to 06-30-2031 04-01-2037 to 06-30-2037
TP001 TREATMENT PLANT 1 CIOC CDS FOR INORGANICS 1 RT 9Y 07-01-2027 to 09-30-2027 07-01-2036 to 09-30-2036
TP001 TREATMENT PLANT 1 CNO3 CDS FOR NITRATE 1 RT YR Monitoring Completed 04-01-2027 to 06-30-2027
TP001 TREATMENT PLANT 1 CTRA CDS FOR RADIUM 1 RT 9Y 04-01-2031 to 06-30-2031 04-01-2040 to 06-30-2040
TP001 TREATMENT PLANT 1 CIOS CDS FOR SECONDARIES 1 RT QT 07-01-2026 to 09-30-2026 10-01-2026 to 12-31-2026
TP001 TREATMENT PLANT 1 CPFA CDS FOR ST PFAS 1 RT YR 05-01-2026 to 07-31-2026 05-01-2027 to 07-31-2027
TP001 TREATMENT PLANT 1 CVOC CDS FOR VOC 1 RT 3Y Monitoring Completed 01-01-2029 to 03-31-2029
Total Number of Schedules Displayed = 12

Non-TCR Individual Schedules

Water System Facility State Asgn ID Water System Facility Name Analyte Code Analyte Name Sample Count Sample Type Sample Frequency Current Monitoring Period Date Range Next Monitoring Period Date Range
DS001 DISTRIBUTION SYSTEM 3014 E. COLI 1 TG 1T 07-22-2026 to 07-29-2026 One Time Monitoring
Total Number of Schedules Displayed = 1

Compliance Schedule

Activity Name Activity Due Date Activity Projected Date Activity Achieved Date Activity Reported Date
TREATMENT BYPASS LINES - DISCONNECT 2011-04-01
STORAGE BYPASS LINE-DISCONNECT 2011-04-01
PUBLIC NOTICE - ISSUE TO CUSTOMERS 2011-07-01
PUBLIC NOTICE - ISSUE TO CUSTOMERS 2012-07-01
OPERATING PERMIT - APPLY FOR PERMIT 2015-05-10
LEAD RESULTS NOTICE CERT 2018-12-29 12-29-2018
LEAD RESULTS NOTICE CERT 2022-12-29 12-29-2022
DO NOT DRINK 2025-10-21
CORROSION CONTROL TRT REC 2026-06-30
CCR ISSUED 2026-07-01 04-01-2026 04-02-2026
CCR CERTIFICATION RECEIVED 2026-07-01 04-02-2026 04-02-2026
PUBLIC NOTICE - ISSUE TO CUSTOMERS 2026-07-11 06-30-2026 06-30-2026
PUBLIC NOTICE - ISSUE TO CUSTOMERS 2026-09-30
CERTIFY LEAD SL NOTIFICATION 2027-07-01 07-01-2027
SOURCE PROTECTION PLAN - SUBMIT TO WSD 2027-07-25
SUBMIT BASELINE SERVICE LINE INVENTORY 2027-11-01 11-01-2027
CORROSION CONTROL TRT INSTALL 2028-06-30
Total Number of Compliance Schedules Displayed = 17

Disclaimer
If the Current Monitoring Period Date Range reads “Monitoring Completed”, sufficient samples have been collected from the specified water system facility (WSF). If the Current Monitoring Period Date Range reads “Monitoring Partially Completed”, sufficient samples have been collected for some but not all the analytes in the group. A monitoring violation may occur if samples were not collected from the appropriate sampling point, were not analyzed by a certified laboratory, or were not reported on time. Total Coliform Rule (TCR), triggered, confirmation or repeat schedules or schedules with a daily or weekly frequency will not display this message.


The Current Date and Time is: Tue Jul 28 04:37:55 EDT 2026